====== Panel Sizes ====== This mainly discusses the dimension for the front panel but in the units used recommended PCB dimensions are noted. ==== Units used ==== These are based on standard rack measurement units, they are: | Height | Rack Units | U | 44.45mm | 1.75" | | Width | Horizontal Pitch | HP | 5.08mm | 0.2" | For Eurorack the height is **3U, 128.5mm**. ==== PCBs ==== The maximum height of the PCB behind this is typically **110mm** giving 9.25mm clearance top and bottom to allow for rack mounts, although 100mm is often used, especially if the PCB is going to a manufacturer such as JLCPCB. The width can be calculated as: **(HP x 5.08) - 0.34** to allow for side clearance. ==== Mounting ==== Mounting holes have a diameter of 3.2mm and are placed as follows: {{ :eurorack:panel.png?400 |}} Note: At 9HP and below only drill holes on the left side are used. ==== Quick Reference ==== ^ HP ^ nominal (mm) ^ actual (mm) ^ | 1 | 5.08 | 5 | | 2 | 10.16 | 9.8 | | 4 | 20.32 | 20 | | 6 | 30.48 | 30 | | 8 | 40.64 | 40.3 | | 10 | 50.8 | 50.5 | | 12 | 60.96 | 60.6 | | 14 | 71.12 | 70.8 | | 16 | 81.28 | 80.9 | | 18 | 91.44 | 91.3 | | 20 | 101.6 | 101.3 | | 21 | 106.68 | 106.3 | | 22 | 111.76 | 111.4 | | 28 | 142.24 | 141.9 | | 42 | 213.36 | 213 |